Troubleshooting: alarm not raised
When an expected alarm doesn't come, the cause is usually in the setup rather than the camera. Work from the camera to the settings.
Check, in this order
- Is the camera working? In Cameras, Last seen should show a recent heartbeat, and the camera should have no open technical alarm. If not, see Troubleshooting: camera offline.
- Is the camera attached to a user? A camera only raises alarms when it is attached. See Attaching cameras.
- Is the camera deactivated? On the user profile, check whether Deactivate camera is on, or whether someone pressed the button on the camera. See Deactivating cameras.
- Is event detection set up? A camera attached for planned supervision only raises no event alarms. See Attaching cameras.
- Do the masks match the room? If the bed or a chair has been moved, the masks may no longer cover it. Consider turning on furniture alarm. See Camera events and Furniture alarm.
- Is the alarm turned on for this event? Check Raise alarm in the alarm settings. Out of bed and Not back in bed can't both be on. See Alarm settings.
- Is it the right time of day? Day and night have separate alarm settings.
- Is the delay running? Not back in bed and Not back in room wait 10 or 20 minutes before raising the alarm.
If your alarms are forwarded to a partner system, the alarm may have been raised but not reached it. Contact Support.
Test after a fix
- Open the video stream to check that the camera works.
- Trigger the event in front of the camera, for example by leaving the bed.
- Open the user's event log and check that the alarm was received. Forwarding to a partner system is shown there too.
- If there is no alarm, check whether the camera sent an event at the time of the test. If it did, the problem is in the alarm settings. If not, it's in the camera or its masks.
Unstable or false alarms
- Many false alarms come from masks that are set up wrong, or from where the camera is placed. See Camera events and Mounting cameras.
- Irregular alarms can come from masks that aren't in use. The camera analyses every mask all the time. Make unused masks as small as possible and move them to the top edge of the picture.
If none of this explains it, contact Support with the user, the camera and the time of the expected alarm.