Skip to content
English
  • There are no suggestions because the search field is empty.

Mounting cameras

Mount a camera that Support has made ready, then attach it to a user. The camera shows in Cameras with the status Inventory when it is ready.

Choose the placement

GuidelineWhy
Mount at 220–250 cm, on the wall or the ceiling. Not higher than 250 cm for event-based supervision.Gives the best angle for detecting movement.
In a bedroom, mount opposite the bed, preferably in the corner opposite it, with the whole bed in view.Seeing the bed from the side makes getting in and out of bed easiest to detect. A corner gives the smallest blind spot.
For general supervision, make sure the face and upper body are clearly visible in the places where the user usually spends time, such as the bed and a chair.Personnel need to see the person.
Aim for the floor, not the ceiling. If a door is in view, the top of the image should be about the top of the door frame. Keep the bed and door away from the edges of the image.Most activity happens on the floor. Make sure to cover the bed and the door.
Mind the blind spot directly below the camera. A table there is fine; a chair or sofa is not.Nothing is detected in the blind spot.
Don't point the camera at reflective surfaces: windows, mirrors, glossy cabinets, chrome, polished floors.IR light reflects back and can blind the camera at night. Mirrors can also cause false alarms.
Avoid direct sunlight or backlight on the lens.Reduces image quality.
Keep curtains, lamps and shelves clear of the lens and the IR light.Blocks the view or the night image.
For a bed with two people, mount on the side where the supervised person sleeps.Keeps the right person in view.

Mount the camera

  1. Mount the camera following the Axis installation guide for the model.
  2. Connect the network cable. With PoE, the same cable gives power and network.
  3. Handle the camera by its edges, and don't touch the lens or the dome in front of it. Clean the lens before you finish.
  4. On dome cameras (P3265-LV, P3275-LV), rotate the lens so the IR light is below the lens and not covered by the edge of the cover. If the image is then upside down, ask Support to rotate it.

Check the camera view

  1. Adjust the camera or lens until all the important areas are in view: bed, chair, door.
  2. Darken the room and check that the night image is clear, with no glare from reflections.

Attach and test

  1. In Cameras, filter by Inventory and check that the camera is there.
  2. Attach the camera to a user. See Attaching cameras.
  3. Open the user's Camera supervision tab and open the video stream. Check that it opens and shows the expected view.

A camera in inventory is reporting but raises no events until it is attached.

Good to know

  • If you rotate a camera after its zones are set, check the zones again. See Camera events.
  • If a camera doesn't appear in Cameras, contact Support.