Escalation

Escalation sends an SMS when an alarm has not been accepted within a set time. It is a second line of response: the recipients are only notified when the first line has not handled the alarm.

For / Required Role: Administrator

Escalation is set on an organisation unit, on the Escalation tab in Organisation. It applies to alarms from all user groups below that organisation unit in the hierarchy.

Set the escalation time

  1. Go to Organisation and select the organisation unit.
  2. Open the Escalation tab.
  3. In Time before SMS is sent (minutes), enter the number of minutes. The minimum is 5 minutes.
  4. Select Update.

Reset removes the time set on this organisation unit.

Add, edit or remove recipients

  1. On the Escalation tab, select Add alarm recipient.
  2. Enter the recipient's Name and Mobile number.
  3. Select Create.

The recipients are listed under Recipients, with name and mobile number.

  • Edit: select the edit button on the recipient's row, change the name or number and select Update.
  • Remove: select the remove button on the recipient's row and confirm with Remove.

Who receives the SMS

When an alarm is raised, TelluCare looks for the closest organisation unit above the user's user group that has recipients. If the alarm is still not accepted when that organisation unit's time has passed, every recipient on that organisation unit receives an SMS.

  • More than one user group: if the user is in several user groups, TelluCare does this for each user group. The recipients found for each user group get an SMS.
  • Released alarms: if an accepted alarm is released, the time starts again from the release. If the alarm isn't accepted again in time, a new SMS is sent.
  • Unplanned supervision: alarms raised from unplanned supervision are not escalated.

The alarm gets a note saying which numbers the SMS was sent to, or that it could not be sent.

Good to know

  • One SMS per alarm, unless it's released. While an alarm waits to be accepted, it is escalated only once.
  • An organisation unit without recipients doesn't stop escalation. The SMS goes to the closest organisation unit above that has recipients.
  • Set escalation as high in the hierarchy as it is valid. It then covers every user group below. Add recipients on a lower organisation unit when part of the organisation needs its own recipients.